在线的最新免费国产_日本一本草久国产欧美日韩_av不卡网站在线免费观看_亚洲国产精品免费爱_噜噜色青草久久丁香伊人_2023亚洲日本国产一区二区_自拍偷拍亚洲动漫_国产一级a爱片在线观看视_欧美.日韩.日本.俄罗斯_天堂久草五月婷婷在线视频

Welcome to the official website of Wuxi Ruiyi Lighting Appliance Co., Ltd.

0086-510-85522050 | +49 15908476791 | +86 13382246779 | +86 18018303926

Contact Us
TEL:+49 15908476791 TEL:+86 13382246779 TEL:18018303926(WeChat) TEL:0086-510-85522050 Email:gy@wuxiruiyilight.de(English.German) Email:ruiyizhaoming@sina.com Add:No. 27, Luou Road, Hudai Industrial Park, Binhu District, Wuxi City P.C.:214161
Present position:Home ? NEWS
The 13 contraindication of the use of UV lamp tube and the matters needing ...
Author: Time:2021-06-30

UV is short for Ultraviolet, and Ultraviolet tubes are short for UV tubes. The spectral range of industrial UV light source is 200nm-450nm, with 365nm as the center. According to the different band, the lamp is divided into UV-A, UV-B, UV-C, each has different uses. UV-A is visible to the naked eye, and the rest is invisible light.

UV lamp is we often say the ultraviolet lamp, it is mainly used for sterilization, medical inspection, product curing, etc., common is used for disinfection of ultraviolet disinfection lamp, its lamp is UV lamp. The application range of UV lamp tube is very wide, such as printing industry, medical industry, wood industry, shoe industry, spraying industry will be used. But in order to use it for a long time, daily maintenance and maintenance is important. Let's take a look at the contraindications of the use of UV lamps.

 

 

 

1: Do not touch the UV lamp directly by hand, so as to avoid scratching or damage, or reduce the life of the lamp;

 

2: wiring direction requirements of the lamp must pay attention to the direction, otherwise it will lead to lamp damage, life reduction or UV lamp surface overheating phenomenon;

 

3: because of the UV lamp inside the pressure is very large, please avoid knocking, scraping and other external forces damage the lamp;

 

4: Do not use it in places with flammable and explosive materials such as thinners, otherwise it will cause fire or explosion;

 

5: the UV lamp in the light do not directly with the naked eye to see, otherwise it will lead to eye prickling or vision loss;

 

6: Do not let the ultraviolet light directly to the skin, otherwise it is easy to cause skin damage by ultraviolet radiation;

 

7: Do not touch the lamp tube that is being lit or just extinguished, otherwise it will cause scald due to the high temperature on the surface of the lamp tube or reflector cover;

 

8: do not paper or cloth and other flammable explosives close to the lamp in use, otherwise it will cause fire due to the high temperature of the surface of the UV lamp;

 

9: Please do a good job of exhaust when the lamp is opened in the sealed space, because the ozone emitted by the lamp has great damage to the human respiratory system;

 

10: try to avoid the phenomenon of frequent opening and closing of UV lamp, each opening and closing will cause consumption of the lamp and reduce the service life of the lamp;

 

11: at least 10 minutes after turning off the lamp before restarting or turning on the lampshade, otherwise it will lead to lamp damage or scald;

 

12: install or replace the UV lamp, clean the lamp shade must turn off the power supply, otherwise it is easy to lead to electric shock;

 

13: when there is a bad cooling condition to troubleshoot in time to continue the operation, otherwise it will seriously affect the service life of the UV lamp.

 

 

 

Installation matters

 

1, before installation to use ethanol to wipe clean the lamp, and then wear clean gloves to hold the lamp.

 

2. Wear the lamp on the cloth mat to install the lamp hole on the card holder. Do not let the lamp touch the metal end plate surface, and let the lamp rub into the cloth. Wiring direction of the UV lamp must pay attention to the direction. Otherwise it will lead to tube damage, life reduction or tube surface overheating phenomenon.

 

3. The lamp tube is installed in place, and the lamp holder is held by hand on the holder for a few times to see whether the lamp tube is free, so that there will be no dilation and cracking phenomenon when the lamp is installed.

 

4, sometimes check the lamp, the UV lamp tube removed observation found that there are traces of hand lines on the wall of the lamp, and can not be wiped off. This is due to the installation of the lamp without gloves, hand sweat and dirt stuck to the lamp after high temperature carbonization sintering quartz glass crystals. In serious cases, leakage at the spot makes the lamp scrap.

 

5, install or replace the UV lamp, clean the lamp shade must turn off the power, otherwise it will be electric shock.

 

6, lamp maintenance in the use of UV lamp, in the appropriate time (1~2 months) with anhydrous ethanol, gauze clean the surface of the lamp and the reflection cover surface of the reflection plate, and then the UV lamp rotation 180℃. The lampshade reflection board will be replaced after losing the mirror effect. The supporting power supply has transformer, capacitor, lamp tube, lamp shade four pieces. Transformer from 2KW-20 several KW can be produced and processed. Transformers are divided into copper and aluminum wires. Capacitors from 18uF to several uF can be customized. Lamps from 200W to tens of kilowatts can be processed production. Chipshade is the length that will decide according to lamp body itself.

 

7. Scientific and reasonable ventilation. Ventilation amount to scientific calculation, the purpose is to UV lamp generated heat suction tube, so that the lamp in the normal temperature environment, not the lower the temperature, the better. Ventilation to heat the lamp cap.

 

8, keep the pipe wall clean, especially to remove oil stains, dust. Because these substances in the high temperature of the tube wall surface will seep into the tube, blocking ultraviolet radiation.

 

9, transformer parameters and lamp parameters to match, voltage, current can not exceed the design index. In particular, the starting voltage should not be too high, generally not more than 40% of the design working voltage